Each write-up point, taken singly, with its repair

Clear a write up

Item 1: clearance to combustibles

A masonry chimney is supposed to keep a gap between its outside face and the wood framing of the house, and the hearth and mantel have their own distances from the fireplace opening. Older South Gate houses were often framed tight to the brick, or a remodel added a wood mantel that sits too close to the flame. The fault is invisible from the room and shows up on a camera run as scorching or as wood touching the masonry.

The fix depends on where the problem is. A mantel can be moved up or swapped for a noncombustible one. Framing too close to the flue usually calls for a listed liner, which changes how hot the outside of the chimney runs and can bring the clearance into line without opening the walls.

Item 2: the flue liner, its size and its condition

Code asks for a liner that is sound, continuous and sized for the appliance it serves. Cracked or offset clay tile fails the first two. A flue that is too small for a wide fireplace opening fails the third, and that is one of the commonest reasons a fireplace smokes into the room: the opening lets in more air and smoke than the flue can carry away.

Repairs range from replacing a few tiles near the top to running a stainless liner the full height of the chimney. When the fireplace is being converted to gas, the insert gets its own liner sized to it, which is part of why a gas insert usually draws better than the open fire it replaced.

Items 3 and 4: the cap and the spark arrestor

The California codes call for a spark arrestor on chimneys that burn solid fuel, and in practice that means a cap with a mesh screen over the flue. Without it, embers can lift onto the roof or into the yard, which matters in Santa Ana wind season. The cap also stops rain, birds and leaves, all of which can choke a flue and turn a fireplace smoky.

Caps run from a simple single flue screen to a custom cover across a wide crown with several flues. A cap that fits the flue and the crown is the plainest code fix on most chimneys and the one we install most often.

  • Mesh on every wood burning flue, sized to the code opening
  • Cap fixed to the flue or the crown, not just set on top
  • Separate screens where flues sit side by side
  • Height set so the cap does not choke the draft

Item 5: water, flashing and the crown

Water is not a smoke fault on its own, but wet brick and wet tile break down, and a broken flue draws badly. Code wants a chimney that sheds water at the top and seals where it meets the roof. A wide chimney on a sloped roof also needs a cricket on its uphill side so water does not pond there.

We list prices for leak repair, for a cricket on its own and for a cricket with new flashing. Crown work, damper replacement and chase covers depend on size and condition, so each one gets a written scope and price before work starts.

Prices for the usual code fixes

Our published ranges for the fixes these items most often call for. Anything outside this list gets a written scope and price first.

Finding and fixing where water gets in
$585 to $3,500
Diverter on the uphill side of the stack
$470 to $1,060
Diverter plus a new metal seal at the roof
$705 to $1,750
Gas burning insert with a liner to the top
$2,900 to $5,850
Camera check to confirm the work
$410
Spark arrestor cap, fitted to the flue or crown
Quoted after we measure

Where the range is wide, the low end is a single flue on an easy roof and the high end is a large or multi flue chimney with harder access.

Code questions we hear

Does my older chimney have to meet today's code?

An existing chimney is not torn out to meet new rules, but an inspector, a lender or an insurer may ask for the items that affect safety: a sound liner, a spark arrestor, proper clearances. Those are the ones we focus on.

My fireplace smokes. Is that a code problem?

Sometimes. A flue too small for the opening, a missing liner or a blocked cap are all code items that cause smoke. A cold flue or a tight house is not. We tell you which.

Is a cap really required?

On a wood burning chimney in California, a spark arrestor is part of the code, and a screened cap is how most chimneys meet it.

Can you confirm the repair for the buyer or the insurer?

Yes. A follow up camera check records the finished work, and the written findings can go to whoever needs them.

Will converting to a gas insert clear the liner item?

Usually, because the insert comes with its own liner run to the top. The old flue still needs to be sound enough to hold that liner, which the camera shows.

Clear the items on your report

Send the inspection items through the contact page. We match each one to a repair, put a price on it and book the work once you approve.

Call (323) 524-5590